Specifications 3 section(s)

Click a section to see products, install method, warranty, and rooms specifying that material.
No CSI spec book in this bid package. Selected sections were not located in any uploaded specs PDF — this project ships drawings only. Refer to the reference sheets (cover sheet, general notes, finish schedule) for product callouts and install notes.
🟫
09 6500
RESILIENT FLOORING
Not found in spec book
🟥
09 6800
CARPETING
Not found in spec book
🟦
09 3000
TILING
Not found in spec book

Materials extracted from drawings (no spec book — pulled from notes)

Even without a CSI spec book, 201 product callouts and 47 code references were pulled from the cover/notes pages on the drawings themselves. = matches your trade scope (9 of 201 products are flooring-relevant). Verify against the source sheets before bidding.
CategoryProductModel / CodeSpec noteCode refSource
flooringCarpet and PadCarpet flooring with pad, 2" stop before nosingA-403
masonryCultured StoneCultured stone with grouted joints on expanded meshA-405
base trimAPC BaseAPC BaseAPC base with mitered corner joints, grout fill cavityA-405
flooringQuarry Tile FloorsQuarry tile floors with seal groutA-440
ceilingGYPSUM BOARD CEILING ON RESILIENT CHANNELS5/8" GYBGypsum board ceiling on resilient channels with non-combustible insulationA-501
drywallGypsum Board5/8"For ceilings on resilient channels and wall sheathing at shear wall locationsA-503
ceilingResilient Channels5/8" GYB ceiling on resilient channelsA-505
ceilingsGypsum Board Ceiling5/8"On resilient channelsA-502
ceilingsAcoustic Ceiling TileACTWhere indicated on reflected ceiling planA-502
Accessible Design ElementsADA Standards for Accessible DesignCommunication elements and features for public accommodations and commercial facilitiesADA Title IIIA-102d
insulationMineral Wool or Glass Fiber InsulationFit tightly between studsA-105
gypsum boardType X Gypsum Board5/8" thickness, typicalA-105
gypsum boardGreen BoardFor wet wall locationsA-105
sealantAcoustical SealantEach side of studs, typicalA-105
framingTreated Bottom Plate2x continuousTreated at first floorA-105
flooringGypcrete3/4" minimum with deckA-105
framingRC ChannelsFor gypsum board mountingA-105
soundproofingSound Board5/8"Layer under gypsum board for sound reductionA-105
gypsum boardType X Gypsum Board5/8"5/8" Type X gypsum board for fire-rated wall assemblies, 1-2 layers per designUL U-301, UL U-905, UL U-311A-104
gypsum boardGreen Board (Moisture & Mold Resistant Gypsum Board)5/8"5/8" moisture and mold resistant gypsum board for bathrooms, wet areas, and pool areasA-104
masonryConcrete Masonry Unit (CMU)8"x16"x8"#5 bar vertical reinforcement, concrete fill at 48" OC horizontally and corners, sand fill other cellsA-104
reinforcementPrefab Reinforcing · Duro-WallDuro-WallPrefab reinforcing for CMU bond beamsA-104
insulationNon-Combustible InsulationNon-combustible insulation for solid fill of floor/ceiling and roof/ceiling ancillary spacesA-104
framingTreated Wood Bottom Plate2xPressure treated wood for bottom plates on ground floorA-104
framingWood Studs2x2x studs per structural designA-104
framingWood Top Plate2x doubleDouble 2x continuous top plateA-104
metal framingRC Channels1.5"1.5" metal RC channels at 24" OC minimum for gypsum board supportA-104
soundproofingSound Board1/2"1/2" sound board beneath gypsum board for sound isolationA-104
fireproofingIntumescent Fireproofing PaintIntumescent fireproofing paint for steel beams and columns at thicknesses required for 1-hour fire ratingA-104
fire protectionAutomatic Sprinkler SystemSupervised automatic sprinkler systemNFPA 13A-104
fire protectionStandpipe SystemStandpipe systemNFPA 14A-104
windowsEncore · Kawneer4 1/2" X 1 3/4" Framing SystemGuestroom windows, clear anodized aluminum exterior/interior/sill flashing, low E thermally brokenA-308
windowsEmerg · QuakerE300 SeriesGuestroom windows, low E thermally brokenA-308
gatesPark Collection Madison Style Gates · CovritMadison StyleSlate Gray Deepwood PVC panel and frame finish with steel pole hinges, glide rings, heavy duty handles, and drop pin locksA-202
concreteConcrete Footing1'-6" diameter x 4'-0" deep concrete footing for gate postsA-202
structuralCMU Wall with Damp ProofingBelow grade level with reinforcing per structural drawingsA-202
coatingStucco CoatingTo match main building finishA-202
hardwareDecorative Post CapFor gate postsA-202
utilitiesGalvanized Pipe1 1/2" galvanized, capped pipe set in concreteA-202
signageAccessible Parking SignInternational Symbol of Accessibility, pole mounted, minimum 48-80 inches above ground levelTAS 502.6A-202
flagpoleFlagpole30'-0" height with steel plate, metal tube, spike, cleat, flag snaps, and halyardA-202
building materialType 'X' Gypsum Wallboard (GWB)5/8"Fire-rated wall assembly materialA-403
stair componentVinyl Stair Nosing1" nosing for stair treadsA-403
structural2x12 Wood Stringers(4) per stair run, do not over-cutA-403
building materialPlywood Risers12"Stair riser materialA-403
structuralCMU (Concrete Masonry Unit)8"x16"x8"Per structural drawings, typicalA-403
trimRound Trim3/4" diameter, 1.5" continuousNon-rated wall at center of stairsA-403
safetyCorner Guard12" height, cut to 3/4" roundStair protectionA-403
building materialWood Treads2xFinish flooring over 2x wood treadsA-403
windowsGL-10GL-10Fixed type, low E thermally broken, U-Factor 0.50, SHGC 0.25A-313
windowsGL-10SGL-10SFixed type, low E thermally broken, U-Factor 0.50, SHGC 0.25A-313
doorsAuto Sliding DoorU-Factor 0.50, SHGC 0.25A-313
storefrontStorefront Type SF1SF1U-Factor 0.50, SHGC 0.25A-313
storefrontStorefront Type SF2SF2U-Factor 0.50, SHGC 0.25A-313
storefrontStorefront Type SF3SF3U-Factor 0.50, SHGC 0.25A-313
storefrontStorefront Type SF4SF4U-Factor 0.50, SHGC 0.25A-313
storefrontStorefront Type SF6SF6U-Factor 0.50, SHGC 0.25A-313
windowsWindow Type W4W4Fixed type, low E thermally broken, U-Factor 0.50, SHGC 0.25A-313
windowsWindow Type W5W5Fixed type, low E thermally broken, U-Factor 0.50, SHGC 0.25A-313
windowsWindow Type W6W6Fixed type, low E thermally broken, U-Factor 0.50, SHGC 0.25A-313
Plumbing - Water ClosetsWater ClosetElongated bowl, seat height 17-19 inches, flush valve operatedADA StandardsA-102c
Plumbing - LavatoriesLavatoryWall-mounted or pedestal, rim height 34 inches maximum, knee clearance 27 inches minimum widthADA StandardsA-102c
Plumbing - SinksKitchen SinkRim height 34-38 inches, knee clearance required, single lever controlsADA StandardsA-102c
Plumbing - Grab BarsGrab Bar1.25-1.5 inch diameter, mounted 33-36 inches above finished floorADA StandardsA-102c
Plumbing - FixturesAccessible Fixture SpacingFixtures spaced minimum 48 inches on centerADA StandardsA-102c
roofingStanding Seam Metal RoofA-404
flooringStamped ConcreteA-404
claddingStone CladdingAdhered directly to concrete columnsA-404
roofing/metalSheet Metal Roof Edge, Fascia and Vented SoffitCanopy applicationA-404
lightingHallmark Lights · HallmarkA-404
ceilingLinear Wood Ceiling (LIN WD CLG)A-404
structuralSteel FramingA-404
structuralSteel BeamA-404
roofingStanding Seam Metal Roof DeckingStanding seam metal roof decking systemA-405
roofingSPR-2SPR-2Over 1/2" treated plywood over metal roof decking, turn perimeter down over fasciaA-405
wood productsTreated Plywood1/2" treated plywoodA-405
flashingDrip Edge Flashing with Flashing Keeper and Continuous Z TrimDrip edge flashing with flashing keeper and continuous Z trim, set Z trim in full bed of sealantA-405
sheet metalSHT MTL-1 Fascia & BracketsSHT MTL-1Sheet metal fascia and brackets attached to wood blockingA-405
soffitPerforated Metal Soffit PanelPerforated metal soffit panel, fully vented and miter cornersA-405
guttersSheet Metal Gutter and BracketsSheet metal gutter and brackets sloped to downspotsA-405
downspoutsDownspout4" x 4" downspout centered on column at each end of canopyA-405
roofingMetal Canopy Ceiling Panel with Galvanized Steel Support FramingMetal canopy ceiling panel with galvanized steel support framing, provide metal J trim at beams and other penetrationsA-405
trimMetal J TrimMetal J trim at beams and other penetrationsA-405
sealantSealantSealant for flashing and construction applicationsA-405
ElectricalGFCI Duplex Receptacle with Integrated Night LightRefer to Design Connect for list of brand-approved devicesA-412
LightingRecessed DownlightRequires GYB housing when penetrating rated horizontal floor/ceiling assemblyA760/15A-412
LightingLED Strip LightingA-412
HVACExhaust Grill12" X 12" Fire RatedA-412
Access ControlAccess Hatch - Fire Rated12" X 12" FDWB - Fire-Rated & Insulated Concealed Frame with Wallboard BeadA-412
HardwareDoor StopFloor mountedA-412
HardwareIn-Wall BlockingCapable of 300 LB load or per code requirement if more stringent; required for all wall-hung furniture, equipment, grab bars, balance bars, A-412
Ceiling MaterialGYP. BD (Gypsum Board)9'-0" A.F.F. ceiling heightA-413
Electrical - ReceptacleGFCI Duplex ReceptacleWith integrated night light; refer to Design Connect for list of brand-approved devicesA-413
Electrical - ReceptacleQuadruplex ReceptacleHalf-switched, optional, only used if installing linear under-cabinet lightA-413
LightingLinear Under-Cabinet Light StripOptional componentA-413
Access PanelAccess Hatch1'-0" x 1'-0" UNOProvide as required for damper access; 12" x 12" FDWB fire-rated & insulated concealed frame with wallboard beadA-413
Door HardwareFloor Mounted Door StopProvide at entry door locationsA-413
Door HardwareDoor ViewerSee door scheduleA-413
Door HardwareSwing Door GuardA-413
Electrical - SecurityCaptive Key Card DeviceOptional, if required by codeA-413
Electrical - SafetySmoke Detector & Sprinkler HeadFire alarm combination horn/visual; wall-mounted in guestroom, typicalA-413
HVACThermostatOpenA-413
Electrical - CommunicationDoor BellIn HA designated rooms onlyA-413
Electrical - SwitchVisual Door Bell Shut-Off SwitchIn HA designated rooms onlyA-413
FurnitureWall-Mounted Amenities DispenserA-413
ElectricalWall SwitchA-411
ElectricalDuplex ReceptacleA-411
ElectricalOccupancy SensorA-411
HVACCeiling Exhaust GrilleA-411
HVACCooling Access PanelA-411
Fire ProtectionFire Alarm/StrobeA-411
ElectricalGFI Duplex/GFI ReceptacleA-411
LightingWALL MOUNT LIGHTDirect-indirectA-415
LightingDRUM DETECTORSurface-mounted, daylight-activatedA-415
PlumbingTOILETElongated, dual-flushA-415
PlumbingSINK FAUCETSingle-handle, wall-mountedA-415
doorsDoorEXP2-PL01Self-closing and tight fitting doors opening to exteriorA-440
door framesDoor FrameEXP2-PT30A-440
door framesDoor FrameEXP2-PL30A-440
partitionsPartitionEXP2-PT05A-440
partitionsPartitionEXP2-PT07A-440
signageSignageEXP2-SS01A-440
wood doorsWood DoorEXP2-WD02A-440
wall panelingWall PanelEXP2-WP01A-440
base trimBaseEXP2-B04Baseboards or coving at all floor/wall juncturesA-440
base trimBaseEXP2-B01A-440
ceilingsGypsum Board CeilingGYB-CLGGypsum board ceiling at 9'-0" heightA-440
caseworkCasegoodEXP2-CG02A-440
plumbingPlumbingEXP2-PL08A-440
plumbingPlumbingEXP2-PL01Water line required for juice machineA-440
fire alarmFire Alarm Combination Horn/VisualA-440
cased openingCased OpeningEXP2-WC06A-440
accessoriesPaper Hand Towel DispenserA-440
accessoriesSoap DispenserA-440
sheathingOSB/PLYWOOD1/2"Weather barrier sheathingA-501
insulationFIBROUS INSULATIONNon-combustible fibrous insulation with continuous vapor barrierA-501
flashingSTAINLESS STEEL SILL FLASHINGSet in full bed of sealantA-501
flashingSTAINLESS STEEL HEAD FLASHINGSet in bed of sealant against air/vapor barrierA-501
exterior wall systemEIFS EXTERIOR WALL SYSTEM1.75" NOM. and 3.25" NOM. thicknessesExterior Insulation and Finish System with drip grooves and offset jointsA-501
flooringGYPCRETE TOPPING1/2"Topping over structural flooringA-501
wall framingWOOD STUD WALL6"6" wood stud wall with 5/8" gypsum boardA-501
window accessoryROLLER SHADE AND BRACKETAt guestroom windows onlyA-501
blockingWOOD BLOCKINGWood blocking with plam-faced 3/4" plywood coverA-501
blockingPLAM FACED PLYWOOD COVER3/4"Removable and replaceable plywood covers at window openingsA-501
insulationINSUL-40Void fill insulation at window openingsA-501
flashingCLEAR ANODIZED ALUMINUM SILL FLASHINGSet in bed of sealantA-501
surfaceSOLID SURFACE SILLFinished sill surfaceA-501
sealantSILL SEALERUnder bottom plateA-501
flashingWEEP SCREEDPer stone manufacturer, typicalA-501
weather barrierMEMBRANE FLASHINGLap and seal membrane flashing over weather barrierA-501
LightingSMOKE DETECTORA-418
HVACEXHAUST FANA-418
HVACDUCT DAMPERA-418
PlumbingGRAB RAILADA COMPLIANTA-418
exterior_wall_systemEIFS (Exterior Insulation and Finish System)Extended insulation with exterior finishA-503
roofingSPR Roofing SystemSingle-ply membrane roofing with flashing systemA-503
flashingSST Sill FlashingStainless steel sill flashing set in full bed of sealant with weeps at 4'-0" O.C.A-503
fireproofingMineral Fiber Fire Proofing WrapApplied to structural steel columnsUL X311 1-hour ratedA-503
structural_framingTreated Wood BlockingFor roof parapet flashing supportA-503
flashingSheet Metal Gravel StopRoof edge termination with flashing keeperA-503
sheathingOSB/Plywood5/8" OSB/Plywood at shear wall locationsA-505
insulationAcoustic Insulation5 1/2"5 1/2" acoustic insulation in floors and ceilingsA-505
framingWood StudWood stud walls with various GYB configurationsA-505
framingWood Floor Joists and Rim BoardsWood floor joists and rim boards per structural drawingsA-505
ceilingSuspended Acoustic or Gypsum CeilingSuspended ACT or GYB ceiling in corridorsA-505
exterior wall systemEIFS EXT. WALL SYSTEMEIFS exterior wall system with weather barrier and fibrous insulationA-504
exterior wall systemEIFS-LSS FINISH SOFFITEIFS-LSS finish soffit with weather barrier and external insulationA-504
flashingSPR FLASH SYSTEMSPR flash system over 1/2" OSB/plywood and support framing cant stripA-504
insulationFIBROUS INSULFibrous insulation with continuous vapor barrierA-504
insulationNON COMB. INSUL.Non-combustible insulation for ceiling applicationsA-504
insulationACOUSTIC INSUL.3.5" acoustic insulationA-504
insulationEXT. RIGID INSUL.EXT. INSUL-2External rigid insulationA-504
drywallGYB5/8" gypsum board on walls and ceilings; 2 layers of 5/8" GYB at shear wall locationsA-504
flooringGYPCRETE TOPPINGGypcrete topping over structural flooringA-504
weatherproofingWEATHER BARRIERWeather barrier material over sheathingA-504
sealantSLNTSealant with weeps at 4'-0" O.C. for stone veneer applicationsA-504
framingFIRE TREATED 6" WOOD STUD WALLFire treated 6" wood stud wall with layers of 5/8" gypsum boardA-504
framingWood Stud Wall6" and 4"Structural framing with double studs at jambs and lintel boxed beams at openingsA-502
flashingStainless Steel Sill FlashingSSTSet in full bed of sealant at sillsA-502
flashingStainless Steel Head FlashingSSTSet in bed of sealant against air vapor barrier and window headA-502
door framesHollow Metal FrameExterior door frameA-502
door framesAluminum FrameStorefront and window framingA-502
doorsADA Compliant Door ThresholdSet in full bed of perimeter sealantA-502
flooringGypcrete Topping3/4"Over structural flooringA-502
structuralStructural Steel ColumnWith applied mineral fiber fire proofing wrap, 1 hour ratedA-502
metal panelsInsulated Aluminum Metal Panel1"Set into glazing pocket, color to match windowA-502
metal panelsFormed Aluminum Metal Panel Column Enclosure1/8"With sealant joints to window mullions, color to match windowA-502
structuralAluminum Angle5/8" x 5/8" x 1/8"Secured to window mullionA-502
foundationConcrete Floor/Foundation with WaterproofingWaterproofing up to floor levelA-502
foundationFoundation Insulation1"Applied to foundationA-502
wall_sheathingTreated Plywood5/8"5/8" treated plywood at shear wall locationsA-506
framingFire Treated Wood Studs6" and 4"6" and 4" fire treated wood stud walls with 5/8" GYB sheathingA-506
exterior_wall_systemEIFSEIFS exterior wall system with 1/4" drip grooveA-506
exterior_finishSynthetic Stone SystemSynthetic stone system exterior finishA-506
flashingSheet Metal FlashingSheet metal gravel stop and parapet flashing with sealantA-506
roofing_accessoriesFlashing KeeperFlashing keeper for roof attachmentA-506
louverELF15J Thin Line Stationary Louver · RuskinELF15JClear anodized aluminum finish with stainless steel screw fasteners and clip brackets top and bottom end and mid point connections. Mid poinA-507
sun screenRectangular Tube Blade Sunshade · RuskinSSRTHClear anodized aluminum finished with 6 inch rectangular tube blades, 10 inch rectangular tube fascia and 10 inch flat bar outrigger.A-507
insulationINSUL-2Stud cavity fill insulation.A-507
exterior wall systemEIFS Exterior Wall SystemExterior Insulation and Finish System.A-507
drywallGypsum Board (Gyp. Bd. / GYB)5/8 inch gypsum board for ceilings and walls.A-507
Applicable codes (47)